Beam Angle
Any directional lamp emits light energy in the shape of
a cone. As you might expect, the CandlePower intensity is the greatest
at the center of the cone and it diminishes the closer it gets to the
edge of the cone; eventually, in theory, to zero. The usable portion of
the cone is defined at the point where the CandlePower falls to 50% of
the CandlePower at the center.
See: Spill Light
|
Beam Spread
Refers to the divergence angle of the light exiting the
lamp. The smaller the number, the tighter and brighter the beam. A
directional bulb or fixture emits a beam that forms a cone. The angle
of that cone is the beam spread of that bulb.
|
Bulb
The bulb refers to the manufactured unit that produces
light. The term lamp is often used in the lighting industry to refer to
the whole unit, while the term bulb refers specifically to the portion
that generates the actual light.
|
Candela
Candela is a measure of how much light is accually produced, as measured at the light source.
The unit of measure used for LED intensity is the millicandela (mcd), 1000 millicandela equals 1 candela. Most
other light sources like the bulbs found in your home use the Lumen, as
the unit of measure. Lumens measure how much light actually falls on a
given surface.
So, how do you convert lumens to mcd ? There is not an exact conversion
since they are different types of measurements but here is a rough
conversion: Divide the number of lumens by 12.57 and you will get the
equivalent candelas, candelas times 1000 = mcd
Incandescent lamps used for interior
lighting generally have an intensity ranging from a few cd to several
hundred cd. The common 40-watt lamp has an intensity of about 35 cd; a
100-watt lamp gives about 130 cd. Note that a 40-watt fluorescent lamp
has an intensity of about 200 cd. The intensity of any lamp depends on
the direction from which it is measured; the average cd power in all
directions in space (spherical candle power) is often given.
|
CandlePower
The unit for measuring the quantity or intensity of
light energy emitted by a directional lamp. Examples of directional
lamps include the narrow spot, spot, flood, wide flood, etc.
CandlePower is expressed in Candelas.
Confusion is caused for some when one manufacturer lists a lamps
CandlePower as "Center-Beam CandlePower" while another notes it as
"Mean CandlePower" while still another uses "Candela" as the heading
for the same information in their Lamp Data Chart. Any of these
listings refer to the lamp CandlePower and are considered to be the
same. CandlePower is used in the Inverse Square Law calculation.
Some texts indicate that 1 candela = 12.57 lumens, however, do not try
to convert lumens to candelas using this formula as the results will be
inaccurate.
CandlePower is used by lighting designers to calculate the foot-candles
illuminating a surface (C.P./distance in feet squared) or Lux
illuminating a surface (C.P./distance in meters squared)
|
| Back to the Top |
Correlated Color Temperature (CCT)
A measure of the apparent color of a light source.
Different light sources described by color temperature as measured in
degrees Kelvin. Lower color temperatures have "warmer" colors closer to
red, and higher color temperatures have "cooler" colors with more blue.
Note: The color temperature of daylight can change throughout the day,
so "Daylight" should not be used as any sort of standard. CCT
measurements should not be confused with color rendering as they are
not associated with each other.
|
Color Temperature
The color of the lamp itself as compared to the color of
a black reference substance when heated to various temperatures Kelvin
and the effect the lamp color has on the color of an objects being
illuminated by it. Note: color temperature does NOT depend on the
intensity of light, just the color of the light.
- Clear blue sky (without direct sun) 12,000K
- Overcast sky 6,500K to 8,000K
- Sunlight (middle of the day) 4,700K to 5,700K
- Cool lamps range from 3,600K to 6,500K
- "Pure" White is about 4,700K
- Metal Halide 4,500K
- Neutral lamps range from 3,000K to 3,600K
- Halogen 3,000K
- Warm lamps range from 2,700K to 3,000K
- House (incandescent) Lamp 2,500K
- Orange color averages 2,300K
- Candle Flame 1,500K
- Fluorescent lamps are available in Daylight (blue tint), Cool white and Warm white (sometimes called "Kitchen & Bath" lamps
- Halogen lamps are considered Neutral.
- Incandescent lamps are considered Warm.
|
Color Rendering Index (CRI)
A measure of how well a light source renders color as
compared to daylight. CRI can only be used to compare light sources
with the same color temperatures. A CRI of 100 would indicate the light
renders the same as daylight at the same color temperature. A CRI in
the upper 90's is considered the best assurance that the light source
will render all colors properly.
For interior design work, only lamps over 80 should be used.
· Fluorescent lamps are available in 50, 60, 70, 80, & 90 CRI.
· Incandescent and Incandescent Halogen lamps are 99 CRI.
|
Coefficient of Utilization (CU Table)
The efficiency in which the luminaire (total light
source) directs lumens to the WorkPlane, expressed as a percentage.
This CU percentage is listed in a table produced by the fixture
manufacturer and is used in the Lumen Method to determine the number of
fixtures required to achieve a given FootCandle level in an area.
|
| Back to the Top |
Daylight
A general term describing the combination of direct
sunlight and skylight. Although considered by some as the best light
for optimal color rendering, the actual color temperature of daylight
will change throughout the day, so it should not be used as any sort of
standard.
|
Dielectric Coating
Microscopic layers of material which alter the transmission and reflection of light through clear glass.
|
Diffuser
A translucent piece of glass or plastic sheet that
shields the light source in a fixture. The light transmitted throughout
the diffuser will be redirected and scattered.
|
Efficacy
The ratio of lumens produced by a lamp vs. the watts
consumed, expressed as lumens per watt. (LPW). The higher the lumens
per watt, the more efficient the lamp.
For example, if a 100-watt source produces 9000 lumens, then the
efficacy is 90 lumens per watt.
|
Electromagnetic Spectrum
Refers to the orderly arrangement of radiant energy by
wavelength or frequency. This spectrum of energy of electric and
magnetic waves has an enormous range that include cosmic rays, x-rays,
illumination, radar, television and power transmission waves. In the
visible light spectrum, the eye is sensitive to radiant energy between
380 nanometers (violet) and 780 nanometers (red). |
Electroluminescent
A light source technology used in exit signs that
provides uniform brightness, long lamp life (approximately eight
years), while consuming very little energy (less than one watt per
lamp).
|
Electronic Ballast
A ballast that uses semi-conductor components to
increase the frequency of fluorescent lamp operation from 60 Hz to
20-40 kHz range. Smaller inductive components provide the lamp current
control. Fluorescent system efficiency is increased due to high
frequency lamp operation.
|
ElectroMagnetic Interference (EMI)
High frequency interference (electrical noise) caused by
electronic components or fluorescent lamps that interferes with the
operation of electrical equipment. EMI is measured in micro-volts, and
can be controlled by filters. Because EMI can interfere with
communication devices, the Federal Communication Commission (FCC) has
established limits for EMI.
|
Fluorescent Phosphors
The color of fluorescent lamps is created by mineral
phosphors in powder form which coat the inside of the lamp tube. The
chemical make-up of these phosphors determines the lamps CRI, its Color
Temperature, and how much light the lamp produces. There are four types
of phosphor coatings:
Traditional halophosphors are inexpensive
coatings which usually provide the entire spectrum of light. But, there
is a trade-off between Color Rendering and Lumen output. Poor color
rendering lamps such as "warm white" and "cool white" have high Lumen
output. Good color rendering lamps such as "warm white deluxe" and
"cool white deluxe" have low Lumen output.
Prime color or Tri-phosphors are very expensive coatings with good color rendering and high lumen output.
Double-coat lamps have a coat of
halo-phosphor and a coat of tri-phosphor. Double-coat lamps which have
a thick tri-phosphor coat are fairly expensive but have very good color
rendering properties. Double-coat lamps with a thin tri-phosphor coat
are much less expensive, but still have full light output and
reasonably good color rendering.
Rare Earth Phosphors Have a thin and
thick coat of rare earth phosphors and are just becoming available. The
CRI for these lamps will be 70, 80, and 90 and in a variety of Color
Temperatures.
|
Foot-candles (Fc)
Measurement of light output in candela per square foot,
or the unit of measurement indicating the light present on a surface or
WorkPlane.. It derives from the early English unit of foot-candle
defined as the illuminance on a surface placed one foot from the
standard candle. 100 foot-candles is generally considered enough light
to perform most tasks.
To convert Fc to Lux, use the formula:
Lux = Fc x 10.76
To convert Lux to Fc, use the formula:
Fc = Lux x .0929
|
FootLambert
The amount of light reflected off a surface. A smooth
white surface reflects approximately 80% of the light while a black
surface reflects only 4%.
|
| Back to the Top |
HID
Abbreviation for high intensity discharge. Generic term
describing mercury vapor, metal halide, high pressure sodium, and
(informally) low pressure sodium light sources and luminaires. |
High Pressure Sodium Lamp
A high intensity discharge (HID) lamp whose light is produced by radiation from sodium vapor and mercury.
|
Illuminance
The concentration of light falling on a surface. Defined
as the luminous flux that is incident from all directions onto a square
meter or Ev = incident luminous flux/surface area receiving it.
illuminance is usually measured in lux.
|
Infrared Radiation (I.R.)
"Infra" meaning frequencies below those of red light.
Essentially, any radiant energy with longer wavelengths than the
visible spectrum. The energy is sensed as heat.
|
Inverse Square Law
A formula used for directional lamps to determine the
relationship between the CandlePower (Cp) of the lamp, the Distance (D)
the lamp is from the surface to be illuminated, and the FootCandle (Fc)
level produced on that surface. If any two of the three elements
are known, the third can be determined.
The formula for Inverse Square Law states
that illuminance varies inversely with the square of the distance from
a point light source. E = 1/r2 Where E is illuminance and r is
the distance. It means that when you double the distance from a
point source of light (like our bulbs) the intensity falls off by a
factor of four. If you triple the distance, the intensity falls
by a factor of nine. You square the distance. This is
helpful in understanding how much the intensity drops off as you mount
a light source further away from the object you want to illuminate.
Example: an island counter top is 3' high
in a kitchen with an 8' ceiling height. Recessed cans (pot
lights) are to be used with a lamp rated at 1150 CandlePower.
The distance from the lamp to the counter surface is approximately 5'.
By squaring the Distance (D2) between the counter and the lamp
(5' x 5' = 25'), then dividing it into the lamps rated CandlePower
(1150), the FootCandle level at the counter surface is found to be 46.
|
Lamp Current Crest Factor (LCCF)
The peak lamp current divided by the RMS (average) lamp
current. Lamp manufacturers require <1.7 for best lamp life. An LCCF
of 1.414 is a perfect sine wave.
|
Lamp Lumen Depreciation Factor (LLD)
A factor that represents the reduction of lumen output
over time. The factor is commonly used as a multiplier to the initial
lumen rating in illuminance calculations, which compensates for the
lumen depreciation. The LLD factor is a dimensionless value between 0
and 1.
|
Light
The visible portion of the electromagnetic spectrum
extending from 380 nanometers (ultra-violet end) to 770 nanometers
(infra-red end). White light is made up of all three primary colors.
The three colors of light are red, blue, and green, and are also called
Additive colors. The Subtractive colors are magenta, cyan and yellow.
|
Light Loss Factor (LLF)
Factors that allow for a lighting system's operation at
less than ideal conditions. These factors are used to calculate
maintained light levels. LLFs are divided into two categories,
recoverable and non-recoverable. Examples are lamp lumen depreciation
and luminaire surface depreciation.
|
Light Output
Also thought of as intensity or brightness. This is
measured in candelas also called candlepower units. Note: The farther
away the light source is, the less intense the perceived light output,
and this process is logarithmic. If you double the distance to the
light source, you will receive only one fourth the radiation.
|
Light Output (Lumen)
The most common measure of light output (or luminous
flux) is the lumen. Light sources are labelled with an output rating in
lumens. For example, a T12 40-watt fluorescent lamp may have a rating
of 3050 lumens. Similarly, a light fixture's output can be expressed in
lumens. As lamps and fixtures age and become dirty, their lumen output
decreases (i.e., lumen depreciation occurs). Most lamp ratings are
based on initial lumens (i.e., when the lamp is new). |
Light Level
Light intensity measured on a plane at a specific
location is called illuminance. Illuminance is measured in footcandles,
which are workplane lumens per square foot. You can measure illuminance
using a light meter located on the work surface where tasks are
performed. Using simple arithmetic and manufacturers' photometric data,
you can predict illuminance for a defined space. (Lux is the metric
unit for illuminance, measured in lumens per square meter. To convert
footcandles to lux, multiply footcandles by 10.76.) |
| Back to the Top |
Low-Pressure Sodium (LPS)
A low-pressure discharge lamp in which light is produced by radiation from sodium vapor.
|
Lumen
The unit of measurement used to indicate the quantity or
intensity of any lamp. Think of it in terms of the lamps raw power.
Lumens are measured at the lamp.
Note: As a light source's color temperature increases, less light is
required to achieve comparable brightness and visual acuity. The lumen
is the international unit to describe the quantity of light (also
called luminous flux). Lumens are used in the Lumen Method calculation
to maintain a given FootCandle level as required for the application.
Some texts indicate that 1 candela = 12.57 lumens, but do not convert
lumens to candelas using this formula as results will be inaccurate.
|
Luminance
A photometric term that quantifies brightness of a light
source or of an illuminated surface that reflects light. It is
expressed as footlamberts (English units) or candelas per square meter
(Metric units). |
Luminaire
A complete lighting unit; an assemblage made up of the fixture and any trim, lenses, reflectors, diffusers and the bulb itself.
|
Luminaire Efficiency
The ratio of total lumen output of a luminaire and the
lumen output of the lamps, expressed as a percentage. For example, if
two luminaires use the same lamps, more light will be emitted from the
fixture with the higher efficiency. |
Lux
The metric unit of measurement indicating the amount of
light present on one square meter of surface or WorkPlane. Lux is the
metric equivalent of the FootCandle. It differs in that instead of
using a sphere with a radius of one foot it uses one meter.
One Lux is equal to the amount of light provided by an ordinary wax
candle on a spherical surface with an area equal to one square meter,
positioned one meter away from the flame.
For reference, 10 lux is generally considered enough light to perform
most tasks.
To convert Lux to Fc, use the formula:
Fc = Lux x .0929
To convert Fc to Lux, use the formula:
Lux = Fc x 10.76
|
Maintained Illuminance
Refers to light levels of a space at other than initial
or rated conditions. This terms considers light loss factors such as
lamp lumen depreciation, luminaire dirt depreciation, and room surface
dirt depreciation. |
Mercury Vapor Lamp
A type of high intensity discharge (HID) lamp in which
most of the light is produced by radiation from mercury vapor. Emits a
blue-green cast of light. Available in clear and phosphor-coated lamps.
|
Metal Halide
A type of high intensity discharge (HID) lamp in which
most of the light is produced by radiation of metal halide and mercury
vapors in the arc tube. Available in clear and phosphor-coated lamps. |
Metamerism
An effect created when objects having different spectral
distributions look alike under one light source but appear different
when viewed with a dissimilar light source.
|
Nadir
Zero angle of light perpendicular to the lamps face and
bisecting the beam angle. Nadir is a line perpendicular to the
illuminated surface and the lamp face.
|
Par Lamp
A parabolic aluminized reflector lamp. An incandescent,
metal halide, or compact fluorescent lamp used to redirect light from
the source using a parabolic reflector. Lamps are available with flood
or spot distributions. |
PAR 36
A PAR lamp that is 36 one-eighths of an inch (4.5") in diameter with a parabolic shaped reflector.
|
| Back to the Top |
Parabolic Luminaire
A popular type of fluorescent fixture that has a louver
composed of aluminum baffles curved in a parabolic shape. The resultant
light distribution produced by this shape provides reduced glare,
better light control, and is considered to have greater aesthetic
appeal. |
Paracube
A metallic coated plastic louver made up of small
squares. Often used to replace the conventional flat lens in a
fluorescent fixture to enhance its appearance. The paracube is visually
comfortable, but the luminaire efficiency is lowered. Also used in
rooms with computer screens because of their glare-reducing qualities.
|
Reflectance
The ratio of light reflected from a surface to the light
incident on the surface. Reflectances are often used for lighting
calculations. The reflectance of a dark carpet is around 20%, and a
clean white wall is roughly 50% to 60%. |
Reflector
The part of a light fixture that shrouds the bulb and redirects some light emitted from the lamp.
|
Refractor
A device used to redirect the light output from a source, primarily by bending the waves of light.
|
Spectral Power Distribution (SPD)
The relative power emitted by a light source as a
function of wavelength, usually shown in graphical format. SPD graphs
provide an easy visual profile of the color characteristics of a light
source. Lights that have relatively even representation across the
color spectrum have the best color-rendering capabilities. Lights with
marked uneveness and spikes will not provide good color rendering.
|
Spill Light
Outside the beam angle is an area of "spill" light. It
extends from the edge of the Beam Angle out to a point in the lamps
cone of light where the CandlePower drops to 10% of the CandlePower at
the center of the cone.
See: Beam Angle
|
Tungsten Halogen Lamp
A gas-filled tungsten filament incandescent lamp with a
lamp envelope made of quartz to withstand the high temperature. This
lamp contains some halogens (namely iodine, chlorine, bromine, and
fluorine), which slow the evaporation of the tungsten. The bulb uses an
inert gas to recycle fragments of burnt off tungsten back to filament.
Also, commonly called a quartz lamp, and the term used to describe an
incandescent lamp or bulb that offers a substantially increased life
compared to a standard incandescent. Also described as quartz
-tungsten-halogen.
|
Ultraviolet Radiation (U.V)
"Ultra" meaning frequencies above those of violet light.
These rays are associated with suntans and fading of pigments and dyes,
and have a colour temperature of 3,500K to 4,100K.
|
Voltage
Electric potential expressed in volts or power/current.
Most American households have electric outlets that have a voltage of
110 to 120 volts.
|
Visual Comfort Probability (VCP)
A rating system for evaluating direct discomfort glare.
This method is a subjective evaluation of visual comfort expressed as
the percent of occupants of a space who will be bothered by direct
glare. VCP allows for several factors: luminaire luminances at
different angles of view, luminaire size, room size, luminaire mounting
height, illuminance, and room surface reflectivity. VCP tables are
often provided as part of photometric reports.
|
Watt
The unit of power or how fast energy is expended over
time or power. One watt is equal to one joule/second of time. A joule =
1 kilogram x meters2 / seconds2. In single phase circuits, it is
related to volts and amps by the formula: Volts x Amps x PF = Watts.
Note: For accurate energy calculations in AC circuits, the PF must be
included. See Wattage Power Factor)
|
| Back to the Top |
Watts
A rating to measure the amount of energy consumed by a lamp. CAUTION:
Do not select a lamp based solely on wattage. This is a very common
mistake. Wattage has little to do with the amount of light produced by
a lamp.
The fact that a bulb uses 100 watts of
energy doesn't mean it gives 100 watts of light. Typically, only 10% or
less of the energy consumed by incandescent lamps is actually used to
produce light. The rest ends up as heat.
In a 120 volt, 100 watt "standard" bulb
with a rated light output of 1750 lumens, the efficiency is 17.5 lumens
per watt. This compares poorly to an "ideal" of 242.5 lumens per watt
for one idealized type of white light, or 681 lumens per watt ideally
for the yellowish-green wavelength of light that the human eye is most
sensitive to.
Most light bulbs average around 500
lumens per 60 Watts. A lumen is the unit of luminous flux equal to the
light emitted in a unit solid angle by a uniform point source having an
intensity of one candela. There is no direct correlation between lumens
and watts because other variables may affect the relationship, such as
lamp design life and fill pressure.
A lamp should be chosen based on its
CandlePower or Lumen rating which indicates the light energy intensity
of the lamp. Only then should wattage be considered to find the most
economical lamp among those lamps powerful enough to provide the proper
FootCandle level on the WorkPlane.
|
Wattage Power Factor
The ratio of AC volts x amps through a device to AC
wattage of the device. A device such as a ballast that measures 120
volts, 1 amp, and 60 watts has a power factor of 50% (volts x amps =
120 VA, therefore 60 watts/120 VA = 0.5). Some utilities charge
customers for low power factor systems. |
Weibull data for lamp life
Weibull distribution has become established as the standard method for
analyzing the life of technical products. Endurance tests on products
without technical faults produce failure curves which represent the
proportion of products that fail in the course of use. Because of their
special properties, these curves can be normalized for the purposes of
comparison. This involves approximating the distributions to a straight
line. To show this, a special coordinate system is needed (named after
Dr. E. H. Wallodi Weibull, 1887 to 1979). Service life distribution can
now be accurately defined by specifying two points on the straight
line, without having to refer to a failure curve.
The following failure rates have been
defined as standard failure rates. The B3 life value represents the
premature failure rate of lamps. It means that 3% of all the tested
lamps failed after this number of hours burned. The Tc life value
represents the failure rate of 63.2% of the lamps. B3 and Tc are of
particular interest in industry. Another important point is the B50
value. This indicates the average life of the lamps (50%).
To show this approximation to a straight
line, a special graphic matrix is needed. The failure rates are
indicated as a percentage plotted against the number of hours burned.
The advantage here is that the distribution of the life of, say, a
headlight lamp can be uniquely defined by specifying particular failure
rates.
Point 1: The B3 life value means that 3% of the tested lamps failed after this number of hours burned.
Point 2: The B10 life value means that 10% of the tested lamps failed after this number of hours burned.
Point 3: The B50 life value indicates the average life of the lamps. The failure rate is 50%.
Point 4: The Tc life value represents the characteristic failure rate of 63.2% of the lamps.
Rule of thumb:
5% overvoltage
- Half the life
- 15% higher luminous flux
- 8% higher power consumption
- 3% higher current
5% undervoltage
- Twice the life
- 15% lower luminous flux
- 8% lower power consumption
- 3% lower current
|
| Back to the Top |
WorkPlane
In any space there is an actual or implied distance from
the light source where the activity to be illuminated takes place,
called the WorkPlane. It is on this WorkPlane that the FootCandle
measurement is taken.
|
Zenith
The direction directly behind the luminaire, at 180° angle to the main direction of light output.
|